|
|
|
|
LEADER |
05447nam a22004333i 4500 |
001 |
EBC6963491 |
003 |
MiAaPQ |
005 |
20231204023224.0 |
006 |
m o d | |
007 |
cr cnu|||||||| |
008 |
231204s2022 xx o ||||0 eng d |
020 |
|
|
|a 9783030975562
|q (electronic bk.)
|
020 |
|
|
|z 9783030975555
|
035 |
|
|
|a (MiAaPQ)EBC6963491
|
035 |
|
|
|a (Au-PeEL)EBL6963491
|
035 |
|
|
|a (OCoLC)1313607053
|
040 |
|
|
|a MiAaPQ
|b eng
|e rda
|e pn
|c MiAaPQ
|d MiAaPQ
|
050 |
|
4 |
|a NA2542.36
|
100 |
1 |
|
|a Azinović, Boris.
|
245 |
1 |
0 |
|a Assessment of Energy-Efficient Building Details for Seismic Regions.
|
250 |
|
|
|a 1st ed.
|
264 |
|
1 |
|a Cham :
|b Springer International Publishing AG,
|c 2022.
|
264 |
|
4 |
|c {copy}2022.
|
300 |
|
|
|a 1 online resource (214 pages)
|
336 |
|
|
|a text
|b txt
|2 rdacontent
|
337 |
|
|
|a computer
|b c
|2 rdamedia
|
338 |
|
|
|a online resource
|b cr
|2 rdacarrier
|
490 |
1 |
|
|a Springer Tracts in Civil Engineering Series
|
505 |
0 |
|
|a Intro -- Preface -- Contents -- 1 Introduction -- References -- 2 Design of the Thermal Insulation Envelope of Energy-Efficient Buildings -- 2.1 »L« Type Structural Assembly Connections -- 2.2 »T« Type Structural Assembly Connections -- 2.3 »+« Type Structural Assembly Connections -- References -- 3 Structural Details in Energy-Efficient Buildings -- 3.1 Foundations on the Thermal Insulation Layer -- 3.1.1 Possible Solutions for Foundations on Thermal Insulation -- 3.1.2 Specifics of Designing Thermally Insulated Foundation Slabs in Non-earthquake-Prone Areas -- 3.1.3 Influence of the Flexible Layer of Thermal Insulation on the Seismic Response of a Building -- 3.2 Base Insulation Blocks for Preventing Thermal Bridges in Walls in Contact with Cold Elements -- 3.2.1 Types of Base Insulation Blocks -- 3.2.2 Influence of Base Insulation Blocks on Better Environmental and Energy-Efficiency Parameters -- 3.2.3 Base Insulation Blocks as Parts of Masonry Structures for Bearing Vertical Static Loads -- 3.3 Details for Preventing Thermal Bridges in Cantilever Structures -- 3.3.1 Precast Element Solutions for Thermal Bridges in Cantilever Structures -- 3.3.2 Comparison of the Environmental and Energy-Efficiency Parameters of an Insulated and Uninsulated Reinforced Concrete Cantilever Slab -- 3.3.3 Selection Principles of Precast Load-Bearing Thermal Insulation Elements Subject to Vertical Static Loads -- 3.4 Building Connection Detail Between the Roof and Outer Wall -- 3.4.1 Environmental and Energy-Efficiency Aspects of the Building Connection Detail Between the Roof and an Outer Wall -- References -- 4 Evaluation of Critical Structural Assemblies -- 4.1 Detail Evaluation Methodology for Energy-Efficient Buildings -- 4.1.1 Importance of Environmental and Energy-Efficiency Parameters -- 4.1.2 Importance of Technical and Structural Parameters.
|
505 |
8 |
|
|a 4.1.3 Importance of External Parameters -- 4.2 Environmental and Energy-Efficiency Parameters -- 4.2.1 Thermal Transmittance of Structural Assemblies (E1) -- 4.2.2 Continuity of Thermal Insulation (E2) -- 4.2.3 Condensation and Thermal Comfort (E3) -- 4.2.4 Influence on the Use of Energy (E4) -- 4.2.5 Airtightness (E5) -- 4.2.6 Life Cycle Assessment (E6) -- 4.2.7 Durability and Sustainability (E7) -- 4.3 Technical and Structural Parameters -- 4.3.1 Load-Bearing Capacity (K1) -- 4.3.2 Minimum Dimensions and Stiffness (K2) -- 4.3.3 Symmetry (K3) -- 4.3.4 Continuity or Uniformity of the Load-Bearing Structure (K4) -- 4.3.5 Eccentricity or a Shift in the Structure According to the Primary Load-Bearing Axis (K5) -- 4.3.6 Capacity Design Method (K6) -- 4.3.7 Connections of Primary and Secondary (Non-)Load-Bearing Elements (K7) -- 4.4 External Parameters -- 4.4.1 Location (Z1) -- 4.4.2 Importance of a Building (Z2) -- 4.4.3 Influence on the Global Analysis (Z3) -- 4.4.4 Complexity of Construction (Z4) -- 4.4.5 Penetrations and Openings (Z5) -- 4.4.6 Economic Aspect (Z6) -- 4.5 Assessment Based on Evaluation Parameters, Weighting Factors and External Parameters -- 4.6 Presentation of the Results -- References -- 5 Case Study: Using Methodology to Assess the Selected Details -- 5.1 Building Connection Detail Between an Outer Wall and the Foundation Slab -- 5.2 Building Connection Detail Between the Load-Bearing Balcony Structure and an Outer Wall -- 5.3 Building Connection Detail Between an Outer Wall and the Unheated Basement -- 5.4 Building Connection Detail Between an Outer Wall and the Roof -- References -- 6 Conclusions -- References -- Appendix Examples of the Use of the Methodology for Evaluating Structural Details.
|
588 |
|
|
|a Description based on publisher supplied metadata and other sources.
|
590 |
|
|
|a Electronic reproduction. Ann Arbor, Michigan : ProQuest Ebook Central, 2023. Available via World Wide Web. Access may be limited to ProQuest Ebook Central affiliated libraries.
|
655 |
|
4 |
|a Electronic books.
|
700 |
1 |
|
|a Kilar, Vojko.
|
700 |
1 |
|
|a Koren, David.
|
776 |
0 |
8 |
|i Print version:
|a Azinović, Boris
|t Assessment of Energy-Efficient Building Details for Seismic Regions
|d Cham : Springer International Publishing AG,c2022
|z 9783030975555
|
797 |
2 |
|
|a ProQuest (Firm)
|
830 |
|
0 |
|a Springer Tracts in Civil Engineering Series
|
856 |
4 |
0 |
|u https://ebookcentral.proquest.com/lib/matrademy/detail.action?docID=6963491
|z Click to View
|